How to re-pressurising expansion vessel on a Vokera combi boiler step by step
B Heating Service B Heating Service
379 subscribers
1,695 views
3

 Published On Nov 20, 2023

How to re-pressurising expansion vessel on a Vokera combi boiler step by step
This video is for GAS SAFE ENGINEERS only, always follow manufacturer instructions.
Before to start any work on gas appliance isolate the power, turn off the gas and the waters.
1. Remove front cover
2. Download manual
3. Drain the boiler
4. Connect compressor to expansion vessel
5. When the boiler pressure drop to 0 bar you can re-pressurise the expansion vessel till 1 bar.
6. Make sure you leave open the drain point.
7. When the boiler pressure is 0 bar, the drain point stopped and the expansion vessel pressure is 1 bar, then it's done.
8. Remove the compressor.
9. Close the drain point.
10. Re-pressurise the heating system till 1 - 1.5 bar.